Please enable JavaScript to view this site.

 

Navigation: DESIGN > DIRTT > Walls > Junctions > Junction Alignment

Changing the Angle of a Wall

Scroll Prev Top Next More

If an angled wall is snapped to to a Junction, Notification 653 appears. Then you can use the Align tool to adjust the angle of the wall.

 

angled_wall

 

1.Select the angled i-Line, and right-click to open Information.

 

angled_wall 2

 

In the Information dialog, you can see how must the angle of the wall is off.

 

angled_wall 3

 

2.To see the angle of the wall, look under Wall Set at the Rotation.

 

angled_wall 4

 

3.To close the Information dialog, click OK.

 

angled_wall 5

 

4.Zoom in close on the all and the Junction.

 

angled_wall 6

 

5.If you want to turn off Action Required Notifications for a clearer view, click the icon on the secondary toolbar.

 

angled_wall 7

 

Action Required Notifications disappear from ICE 2D.

 

Caution: Remember to turn your Notifications on after you change align the wall so that you can confirm that you fixed the angle of the wall.

 

6.Select the wall, and right-click to choose Align.

 

angled_wall 8

 

Assistance text appears in the top-left corner of ICE 2D, asking you to select a target point. Available target points are outlined blue. When you hover your mouse over a possible target point, it becomes a solid blue circle.

 

7.Select the target point on the wall that you want to straighten.

 

angled_wall 9

 

The assistance text in the top-left corner of ICE 2D updates, asking you to select a reference. Available reference points are outlined in purple circles. When you hover your mouse over a possible reference point, it becomes a solid purple circle.

 

8.Select a reference point on the Junction.

 

angled_wall 10

 

After you select your target and reference points, ICE updates to display reference dimensions and angles. You can use these dimensions and angles to re-align the selected i-Line.

 

9.Click on the angle that you want to change.

 

angled_wall 11

 

10.In Confirm Angle, enter a new angle, and click OK

 

junctions 43

 

You see a preview of your updated angle.

 

angled_wall 12

 

11.Press Enter.

 

The angle of your wall updates.  wall moves to line up with Junction.

 

angled_wall 13

 

12.If you turned the Action Required Notifications off, click on the icon on the secondary toolbar to turn them back on.

 

angled_wall 14

 

13.Confirm that Notification 653 is gone and that no other notifications appear.

 

Caution: When you change the angle of a wall that is snapped to a Junction, the wall may unsnap from the Junction, causing Notification 635 to appear. You can open the Junction Alignment Info dialog to see which wall has unsnapped from the junction.

 

angled_wall 16

 

14.If Notification 635 appears, re-snap the wall to the Junction.

 

angled_wall 15

 

Related Links:

Viewing Junction Alignment Info

Moving a Wall to Snap to a Junction

 

Topic last updated on 3/16/2023.